Technical parameters
- Control range: -50 ~ 110
- Input Power: DC 12V
- Resolution: -9.9-99.9 0.1 , other temperature ranges 1
- Measuring inputs: NTC (10K 0.5%) Waterproof sensor 0.5M
- Measurement accuracy: 0.1
- Output range: 1 way 10A relay
- Control accuracy: 0.1
- Environmental requirements: -10-60 , humidity 20% -85%
- Hysteresis accuracy: 0.1
- Size: 48 * 40mm
- Refresh rate: 0.5S
- Power consumption: Static current: <= 35MA,attract current:<= 65MA
- Temperature protection :0-110
- Display Type: 0.28 ” three digital display tube
How to use:
- Lights, LED status descriptions: Indicator: Off The relay is switched off, Always indicate the relay is closed. LED: Shows LL is the sensor open, showing HH is out of range, the thermostat will be forced to close the relay, the display — as high temperature protection.
- Parameter Function: Long press SET 5 seconds to enter the main menu settings, press the + – toggle P0 … P8. Long press SET or 10 seconds of no key activity confirmed their return to the controller
Code Code Description Setting range Factory setting
P0 Cooling /Heating C/H C
P1 Hysteresis setting 0.5-15 2
P2 Highest setting upper limit 110 110
P3 Lowest setting upper limit -50 -50
P4 Temperature correction -7-7 0
P5 Delay start time 0-10 Minutes 0
P6 High temperature alarm 0-110 OFF
Off state, long press + – boot to restore the factory settings